
Pellet Vegas combines innovation and aesthetic design, offering maximum...







Ostatnio przegl膮dane
Subcategories in category "Equipment":
Pipes in a central heating system perform variety of functions depending on the destination:
The following categories will help to find water pipes to expand the central heating system (hot water transport from the boiler room into a building or industrial building) or to build or expand a chimney flue installation (exhaust flue connection) with:
Central heating steering devices manage the process of production and distribution of heat in a heating system. Boiler controller tasks are to maintain optimal operating parameters to enable economical and clean heating. Providing comfortable heating is not only a maintenance-free operation of a central heating boiler but also keeping the temp. at a constant user-defined level of the temperature settings and maintain it over time.
Basic central heating controllers for hand fired boilers control the central heating pump and the blower fan. More advanced central heating controller versions take control over the boiler feeder and additional pumps (like a circulation pump, floor heating pump) and mixing valves. Some central heating controllers can be extended with an internet network and GSM module for more user control. The most powerful boiler controllers have the possibility of connecting multiple sensors to support the combustion process like the lambda sensor (probe) measuring the oxygen level, weather sensor measuring the outdoor temperature, exhaust gas temperature sensor for the PID algorithm and advanced FUZZY LOGIC steering functions.
Electronic room temperature controller is a device that allows programming a certain room temperature level, which is requested by the user.
A simple room thermostat controller allows you to program the temperature usually in several modes, eg. day mode or night mode (economy) or weekly work schedule (individual setting hours for the operation of the controller peaceful with higher and lower temperature period).
More advanced models of room temperature controllers might have additional modes operating modes like vacation mode, party mode, frost protection. Depending on the room temperature controller model can be wireless communication or traditional (low-twisted-pair cables or through RS).
The temperature sensor in the thermostat room thermostat gets the indication height of the room temperature and compares it with the one set by the user. When the temperature reaches to the desired setpoint, then the room temperature controller sends a feedback to the central heating controller of the need to stop the central heating pump or switch off the boiler.
In advanced models (usually room temperature controllers based on RS communication) room temperature controller has the ability to control a mixing valve and domestic hot water temperature.
Room regulators from the top shelf have a beautiful and aesthetic device design with a color LCD display, with the flush-mounting technique it can beautifully work like an electronic picture frame (a screen saver in the form of a slide show).
Central heating protection equipment, devices and accessories for central heating installation, boiler or stove. Thermostatic and cooling valves, cooling coils of BVT, BVTS and WZS type. Water extinguishing system for coal or pellet boiler. Afterdamp detector for boiler or fireplace. Thermal protection accessories for central heating system connections, heat sealants and other related accessories with the safety of a boiler, fireplace, furnace and central heating installation.
Electric immersion heaters are used to prepare domestic hot water. Immersion heater fulfils its task if, for example, the heat pump in winter can not deliver the right amount of heat. In a hot water storage tank, an electric immersion heater is useful in the summer, when the central heating is not used or when the produced by the solar panels hot water on cold days is insufficient. Despite cheaper ways of obtaining heat, an electric immersion heater is still a popular reserve method of heating water for utility purposes in homes or offices.
High-temperature sealants for boilers, fireplaces and smoke pipes will allow to protect and seal the connections and flue gas adapters for heating devices in boiler rooms and central heating installations.
Heat-resistant tapes and adapters are used to make safe and fire-resistant passages in chimney installations for discharging exhaust gases from boilers or fireplaces.
I-1m mixing valve module from tech. Three-way or four-way valve control and valve pump. Cooperation with main controllers via RS communication.
Temperature sensor C-7p from Tech. Compatible with the L7 controller.
Tech R-8b wireless room regulator, which works with the L-8 slat
ST-294v1 / 2 room regulator from Tech is designed for controlling the heating device. The regulator has a built-in room sensor.
Room regulator ST-292v2 / 3 from Tech. Regulator control heating (or cooling) device by sending a signal (information) to boiler. It is possible to set weekly, day / night or manual program.
Two-state room regulator Tech ST-295v2 / 3. Function of the regulator is to maintain the set room temperature. Available wired or wireless version.
ST-513 controller-integrator outputs from Tech. Integration of five voltage inputs, control of one 230V output
Wireless outdoor temperature sensor C-8zr from TECH to the L-8 strip
R-8 wireless bistable room regulator from Tech, which works with the L-8 bar
Wireless C-2 window opening sensor from Tech
Tech MW-1 executive module. The module's task is to enable / disable contact in moment when receive information from controller. Depending on controller, module can, for example, switch on the boiler, pump, and actuator.
The executive module Tech MW-1 230V. The module's task is to enable / disable contact in moment when receive information from controller. Depending on controller, module can, for example, switch on boiler, pump, and actuator
R-9s wired room regulator Tech, which cooperates with the L-9 strip. The regulator is responsible for maintaining the set temperature in a given room.
Wired controller for thermostatic actuators L10 from Tech designed for valve operation.
R-10b wired room regulator Tech, which cooperates with the L-10 strip SERIES 10