Combiner box AC Legrand with Dehn 1+2 surge suppressor, EATON FR 125A, C63A 3+N, 3x6A, B16A 30mA, B10A, phase sig, outlet

Combiner box AC Legrand with Dehn 1+2 surge suppressor, EATON FR 125A, C63A 3+N, 3x6A, B16A 30mA, B10A, phase sig, outlet View larger

5905515627443

SHD-1471 AC

Manufacturer: PROSAT
PROSAT

807,17 USD

Payment and delivery

Transport Costs: Individual calculation
(After placing your order we will send you a non-binding offer containing delivery costs.)

Payment methods for the goods:

Bank transfereligible for a 2% discount for orders from Poland (others without discount)
P24 – operator’s payment gateway, no discount for orders from Poland, others +2%

Add to wishlist

Total Rating Total Rating:

0
0/5 - 0 reviews

View ratings
0 1 2 3 40
0 1 2 3 00
0 1 2 0 10
0 1 0 1 20
0 0 1 2 30

 Add Review View Reviews View Reviews

Data sheet

Warranty2
Width [mm]319.000
Height [mm]144.000
Length [mm]384.000
Weight [kg]5.200
IP protection class65
Type of connection switchboardAC
Number of phases - protection 13
Number of overcurrent circuit breakers - protection 11
Rated current of the overcurrent circuit breaker - protection 163
Type of AC surge arrester1+2
Housing size24
Whether an AC surge arrester is used1
AC surge arrester usedDehn
Rated discharge current of AC surge arrester12.5
Rated insulation voltage of the housing400 V AC, 1500 V DC
Tripping characteristic of the overcurrent circuit breaker - protection 1C
Number of fields of AC surge arrester4
Number of overcurrent circuit breaker boxes - protection 14
Rated residual current of RCD30
Number of RCDs used1
Triggering characteristics of the RCDA
Phase signaling used1
Number of phases - protection 21
Number of overcurrent circuit breakers - protection 23
Rated current of the overcurrent circuit breaker - protection 26
Tripping characteristic of the overcurrent circuit breaker - protection 2B
FR insulating switch disconnector used125
Number of fields of the FR insulating switch disconnector3
Applied socket1
Number of phases - protection 33
Number of overcurrent circuit breakers - protection 31
Rated current of the overcurrent circuit breaker - protection 310
Tripping characteristic of the overcurrent circuit breaker - protection 3B
Number of overcurrent circuit breaker boxes - protection 21
Number of overcurrent circuit breaker boxes - protection 33

ℹ️ Viewed reviews are moderated. We do not verify that they come from customers who have purchased the product.

 Reviews about Combiner box AC Legrand with Dehn 1+2 surge suppressor, EATON FR 125A, C63A 3+N, 3x6A, B16A 30mA, B10A, phase sig, outlet (0)