Combiner box for AC connection with Dehn surge arrester type 1+2, FR 125A with rise trip, RCD 63A 300mA type A, B25A 3-F, RCD

Combiner box for AC connection with Dehn surge arrester type 1+2, FR 125A with rise trip, RCD 63A 300mA type A, B25A 3-F, RCD View larger

5905515631891

SHD-1624 AC

Manufacturer: PROSAT
PROSAT

2 209,82 USD

Payment and delivery

Transport Costs: Individual calculation
(After placing your order we will send you a non-binding offer containing delivery costs.)

Payment methods for the goods:

Bank transfereligible for a 2% discount for orders from Poland (others without discount)
P24 – operator’s payment gateway, no discount for orders from Poland, others +2%

Add to wishlist

Total Rating Total Rating:

0
0/5 - 0 reviews

View ratings
0 1 2 3 40
0 1 2 3 00
0 1 2 0 10
0 1 0 1 20
0 0 1 2 30

 Add Review View Reviews View Reviews

Data sheet

Warranty2
Width [mm]600.000
Height [mm]300.000
Length [mm]800.000
Weight [kg]38.000
IP protection class66
Type of connection switchboardAC
Number of phases - protection 13
Number of overcurrent circuit breakers - protection 11
Rated current of the overcurrent circuit breaker - protection 125
Type of AC surge arrester1+2
Housing sizeIP66 FIBOX 7050
Whether an AC surge arrester is used1
AC surge arrester usedDehn
Rated discharge current of AC surge arrester12.5
Rated insulation voltage of the housing1000 V AC, 1500 V DC
Tripping characteristic of the overcurrent circuit breaker - protection 1B
Number of fields of AC surge arrester4
Number of overcurrent circuit breaker boxes - protection 13
Rated residual current of RCD300
Number of RCDs used1
Triggering characteristics of the RCDA
Number of triggers1
Trigger typeWzrostowy
Number of phases - protection 23
Number of overcurrent circuit breakers - protection 21
Rated current of the overcurrent circuit breaker - protection 280
Tripping characteristic of the overcurrent circuit breaker - protection 2B
FR insulating switch disconnector used125
Number of fields of the FR insulating switch disconnector3
Number of phases - protection 31
Number of overcurrent circuit breakers - protection 31
Rated current of the overcurrent circuit breaker - protection 310
Tripping characteristic of the overcurrent circuit breaker - protection 3B
Number of overcurrent circuit breaker boxes - protection 23
Number of overcurrent circuit breaker boxes - protection 31

ℹ️ Viewed reviews are moderated. We do not verify that they come from customers who have purchased the product.

 Reviews about Combiner box for AC connection with Dehn surge arrester type 1+2, FR 125A with rise trip, RCD 63A 300mA type A, B25A 3-F, RCD (0)

30 other products in the same category: