Wood pellets boiler Viadrus A0C is an automatic boiler available in two sizes - 5 and 7 sections. Its important advantage is extraordinary high efficiency up to 86.9 % and automatic ignition as well.Fuel:

  • wooden pellets

Advantages:

  • long life of the cast-iron boiler body
  • optional huge pellet hopper
  • efficiency up to 86.9%
  • meets the emission class 4 according to EN 303-5 standards
  • optional remote control over the internet
  • optionally supplied assembled or unassembled
  • reasonable price and high quality
Manual controller

Features of the S.Control

Configuration wizard

  • Fast and easy configuration in several steps
  • Air and fuel parameters are matched automatically

Display

  • High class graphical display
  • Graphical and text menu

Information

  • Alarm and error history
  • Reading of flame brightness
  • Fuel quantity in the hopper
  • Current fuel consumption
  • Current burner power
  • Info key for quick help
  • Alarm sound signalling
  • Clock with calendar

Inputs/Outputs

  • Central heating pump
  • Domestic hot water pump with temperature sensor
  • Mixing valve with temperature sensor
  • Outdoor temperature sensor
  • Room thermostat
  • Boiler thermostat (Gas/Oil)
  • Pressure sensor for flue gas fan monitoring
  • Flue gas temperature sensor
  • Safety temperature limiter

Extensions

  • For mixing valves with temperature sensors
  • Domestic hot water circulation pump
  • Buffer circuit charging pump with temperature sensors
  • Main hopper feeder with fuel sensor
  • Lambda Control
  • Net Control
Color display

Features of the S.Control TOUCH

onfiguration wizard

  • Fast and easy configuration in several steps
  • Air and fuel parameters are matched automatically

Display

  • High class colour, touch display
  • Graphical and text menu

Information

  • Alarm and error history
  • Reading of flame brightness
  • Fuel quantity in the hopper
  • Current fuel consumption
  • Current burner power
  • Info key for quick help
  • Alarm sound signalling
  • Clock with calendar

Inputs/Outputs

  • Central heating pump
  • Domestic hot water pump with temperature sensor
  • Mixing valve with temperature sensor
  • Outdoor temperature sensor
  • Room thermostat
  • Boiler thermostat (Gas/Oil)
  • Pressure sensor for flue gas fan monitoring
  • Flue gas temperature sensor
  • Safety temperature limiter

Extensions

  • For mixing valves with temperature sensors
  • Domestic hot water circulation pump
  • Buffer circuit charging pump with temperature sensors
  • Main hopper feeder with fuel sensor
  • Lambda Control
  • Net Control

Dimensions, technical parameters of the boiler

Boiler type-A0C-X20P-00.16
Sections numberpcs.5
Boiler weight (incl. the reservoir)kg356
Water contentl62
Chimney throat diametermm156
Boiler dimensions (incl. the reservoir): width x depth x highmm1258 x 1207 x 1345
Boiler dimensions (incl. the reservoir and the economizer): width x depth x highmm1258 x 1639 x 1345
Diameter of the filling hole for manual fillingmm500
Diameter of the filling hole for automatic fillingmm50
Operation water overpressurebar4
Testing water overpressurebar8
Recommended operation heating water temperatureºC65 - 85
Minimum return water temperatureºC55
Cold water temperatureºC10
Overpressure for the safety heat-exchanger (DBV 1 – 02)bar6
Boiler hydraulic loss (at ΔT 20 K)mbar0,677
Hydraulic resistance coefficient8,155
Noise leveldBNot exceeding the level of 65 dB (A)
Chimney draughtmbar0,10 - 0,20
Boiler connections – heating water – return waterG 1 ½" (6/4")
Supply voltage1/N/PE 230V AC 50 Hz TN - S
Electric coverIP 40
Electric energy consumption at the nominal powerW43

Heating technical parameters of the boiler

Boiler type-A0C-X20P-00.16
Sections numberpcs.5
Nominal powerkW20
Fuel consumption at the nominal powerkg/h4,9
Flue gases temperature at the nominal power - A0C-SXP/ A0C-AXPºC211/113
Minimum powerkW6,4
Fuel consumption at the minimum powerkg/h1,5
Flue gases temperature at the minimum power - A0C-SXP/ A0C-AXPºC114,5/74
Minimum chimney draughtmbar0,14
Fuel heating powerMJ/kg16,78
Effectiveness - A0C-SXP/ A0C-AXP%83,3/90
Mass flow rate of flue gases on the output side - A0C-SXP/ A0C-AXPkg/s0,014/0,014
Boiler class according to EN 303-5 - A0C-SXP/ A0C-AXP4/5
Energy efficiency classA+
VIADRUS Boiler
  1. Front section
  2. Central section
  3. Rear section
  4. Stocking door (with a rosette of primary air)
  5. Ash door
  6. Chimney pot
  7. Burner sealing
  8. Burner PellasX
  9. Connecting hose
  10. Feeder
  11. Reservoir
  12. Cladding (complete)
  13. Control cabinet
  14. Regulator control elements
  15. Heating water pipe
  16. Ash-pan
  17. Burner flange
  18. Flange insulation
  19. Return water pipe
  20. Baffle
  21. Upper insulation of the stocking door
  22. Bottom insulation of the stocking door
  23. Upper insulation of the ash door
  24. Bottom insulation of the ash door
  25. Securing valve
  26. Burner pipe
  27. Bushing

Data sheet

Number of segments5
Efficiency [ % ]86,9
Class4, 5, A+, BImSchV 2
Weight [ kg ]356
Depth [ mm ]1,207
Exhaust gas pipe size [ mm ]156
Water capacity [ L ]62
Outlet and inlet supply size [ inch ]64''
InstallationVertical, Floor, Internal
Max. working temperature [ °C ]85
Min. working temperature [ °C ]55
Max. operating pressure [ bar ]4
Min chimney draft [ Pa ]10
FeederOPTIONAL
BurnerChute
SteeringOPTIONAL, remote, via web browser, via the Internet
Mains voltage [ V ]230
Fuelpellets, YES
Warranty2 years for components, 5 years for tightness of the heat exchanger
Otherautomatic fuel igniter