⛔ Product unavailable
Warning: Last items in stock!
Availability date:
QmPell is designed to provide right heating for every family. It is perfect for use in single family houses and utility rooms. Boiler has been designed to meet latest emission standards and to improve fuel feeding process. QmPell is made of 6mm thick boiler steel and an intelligent control system.
QmPell series is an innovative achievement by designers in the fields of performance, automation of operation and environmental care. Thanks to its compact design, the boiler can be adapted to any boiler room. New design of exchanger significantly reduces heat loss and reduces the need for cleaning.
The role of controller in QmPell series is played by the COBRA 2, which is infinitely adjustable and operates 2 pumps (central heating, hot water and floor), a mixing valve actuator and a temperature limiter (STB). It is also responsible for starting up boiler, controlling power level and cleaning. A new, innovative method of overpressure combustion, protecting against flashback and constant temperature monitoring guarantee increased safety of use.

| Technical data | Unit | Model | |||
| 8 | 12 | 18 | |||
| Dimensions | D | [mm] | ∅ 127 | ||
| L1 | 785 | 795 | |||
| L2 | - | 873 | |||
| L | 452 | 463 | |||
| H | 1479 | 1184 | 1384 | ||
| H1 | 936 | 1002 | 1232 | ||
| H2 | 905 | 981 | 1209 | ||
| H3 | 90 | 958 | 1186 | ||
| H4 | - | 79 | |||
| S | 430 | 500 | |||
| S1 | 487 | 484 | |||
| Primary fuel | — | wood pellet class A1 according to EN14961 humidity ≤ 10% ash content ≤ 0,7% diameter 6±1 mm, length 3,15-40 mm Ash melting point ≥1200°C calorific value ≥ 16,5 MJ/kg | |||
| Heat output range | [kW] | 2,3-8,1 | 3,2-12,2 | 3,8-17,5 | |
| Cubic capacity of heated rooms | [m3] | 250 | 400 | 625 | |
| Area of heated premises | [m2] | 100 | 160 | 250 | |
| Basket filling capacity | [L] | 60 | 140 | 180 | |
| Boiler water capacity | [L] | 40 | 50 | 80 | |
| Maximum operating pressure | [bar] | 2 | |||
| Minimum chimney draught required | [mBar] | 0,2 | |||
| Exhaust gas temp. | Nominal power | [°C] | 141,5 | 136,2 | 130,8 |
| Minimum power | 84,9 | 72,4 | 72,5 | ||
| Exhaust mass flow | Nominal power | [g/s] | 7,09 | 10,00 | 13,00 |
| Minimum power | 2,70 | 4,00 | 5,00 | ||
| Fuel consumption at nominal output at calorific value 17 MJ/kg | [kg/h] | 2,08 | 2,76 | 4,01 | |
| Water flow resistance at nominal power | ΔT=10K | [mbar] | 43,00 | 45,00 | 75,00 |
| ΔT=20K | 47,30 | 43,00 | 68,00 | ||
| Supply water temperature | [°C] | min. 57 / max. 85 | |||
| Boiler power supply 230 V – 50 Hz / 400 V – 50 Hz | [W] | < 1055 | |||
| Electrical power | 55 | ||||
| Standby power | 1 | ||||
| Power consumed at 30% load | 20 | 4 | 3 | ||
| Power consumed at 100% load | 29 | 27 | 38 | ||
| Noise | [dB] | < 65 | |||
| Boiler weight without water | [kg] | 180 | 241 | 280 | |
| Diameter of supply and return connections | — | GW 1” | |||
| Thermal efficiency according to PN-EN 303-5:2012 (nom. power – min. power) | [%] | 89,9 – 90,0 | 91,0 – 91,7 | 90,0 – 89,0 | |
| Energy class | [%] | A+ | |||
| Controller/fan | - | YES / YES | |||
| Boiler operation under pressure [N] / vacuum [P] of flue gases at outlet | - | N | |||
| Warranty | - | 10 years of joint tightness 60 months leakage of exchanger 24 months for components | |||
| Heat exchanger material | - | Steel P265GH PN-EN 10028 | |||
| Temperature setting range on controller | [°C] | 40 – 80 | |||
ℹ️ Viewed reviews are moderated. We do not verify that they come from customers who have purchased the product.