⛔ Product unavailable
Warning: Last items in stock!
Availability date:
The boilers meet the energy and emission requirements of class 5 of PN EN 303-5: 2012 standard and have the Ecodesign Certificate.

Type / Dimensions | A | B | C | D | E | F | G | H | I | J | K1 | K2 | L1 | L2 | M | N |
| 10 | 496 | 1151 | 1376 | 1376 | 1396 | 995 | Ø159 | 630 | 740 | 835 | 158 | 173 | 121 | 391 | 258 | 381 |
| 14 | 496 | 1151 | 1376 | 1376 | 1396 | 995 | Ø159 | 630 | 740 | 835 | 158 | 173 | 121 | 391 | 258 | 381 |
| 20 | 546 | 1201 | 1426 | 1426 | 1446 | 1045 | Ø159 | 630 | 720 | 815 | 158 | 173 | 121 | 441 | 258 | 431 |
| 25 | 546 | 1201 | 1476 | 1476 | 1496 | 1100 | Ø159 | 770 | 860 | 960 | 158 | 173 | 121 | 441 | 258 | 431 |

Pellet burner with automatic cleaning function in standard

5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler

High thermal efficiency reaching 94% due to increased heat recovery from flue gases

Heat exchanger made of certified high-grade boiler steel

ADAPTIVE CONTROL control - adjustment of boiler operation based on air flow through the heat exchanger

Fuel self-ignition system

Compact dimensions

Ceramic catalysts stabilising combustion process

APC K SLIM ADAPTIVE CONTROL controller servicing three pumps /central heating, domestic hot water, floor/. Control of one mixing valve; preview and change of parameters of the main ONLINE controller - extra payable option

Boiler adapted for installation in the closed system provided that protections were installed in accordance with the operation and maintenance manual of the boiler

Model of boiler | Defro Spectra | ||||
Specification / type of boiler | J.m. | 10 | 14 | 20 | 25 |
Nominal power | kW | 10 | 14 | 20 | 25 |
Power range | kW | 3,0-10 | 4,2-14 | 5,7-20 | 7,2-25 |
Boiler weight | kg | ~340 | ~350 | ~372 | ~467 |
The boiler class according to PN-EN 303-5: 2012 | - | 5 class | |||
ECODESIGN | - | Yes | |||
Energy class | - | A+ | |||
Basic fuel | - | pellets Ø 6-8 mm | |||
Fuel class | - | biogenic fuel - C1 | |||
Heating surface | m2 | 1,5 | 1,8 | 2,3 | 3,0 |
Area of heated rooms 1) | m2 | to 125 | to 175 | to 240 | to 300 |
Disposable fuel charge | kg | ~68 | ~68 | ~81 | ~112 |
Fuel container capacity 2) | kg | ~141 | ~141 | ~152 | ~199 |
Fuel consumption 3) | kg/h | 2,1 | 2,7 | 4,2 | 5,0 |
Optimum thermal efficiency | % | ~94,7 | |||
Max. permissible work pressure 4) | bar | open system 1,5 /close system 2,5 | |||
Required flue gas draught | Pa | 20 | 23 | 26 | 28 |
Water temperature on supply max. | °C | 65/90 | |||
Flue gas temperature for nominal power | °C | 88,6-117,5 | |||
Water capacity of the boiler | l | 65 | 63 | 71 | 103 |
Chimney section | cmxcm | 14x14 | 14x14 | 14x14 | 15x15 |
Chimney section | Ø mm | 160 | 160 | 160 | 170 |
Minimum chimney height | m | 6 | 6,5 | 7 | 7,5 |
The dimensions of the loading opening of the fuel container | mm | 550x345 | 550x345 | 550x345 | 550x435 |
Power consumption work / start-up | W | 83/383 | |||
Power | V/Hz | ~230V/50Hz | |||
Width | mm | 1151 | 1151 | 1201 | 1201 |
Depth | mm | 835 | 835 | 815 | 960 |
| Height 5) | mm | 1396 | 1396 | 1446 | 1496 |
Height to the bottom edge of the exhaust outlet | mm | 995 | 995 | 1045 | 1100 |
Release socket diameter | - | ½’’ | |||
Diameter of the exhaust gas socket | mm | 159 | |||
1) Maximum area of heated rooms estimated for unit heat demand q=80 W/m2
2) Fuel tank capacity for pellet bulk density 0,6 kg/dm3.
3) Fuel consumption for pellets with a calorific value of 17,000 ± 300kJ / kg.
4) The condition of installation in a closed system is the use of thermal protection, eg DBV-2.
5) The height of the boiler can be adjusted using the attached feet. The feet have a 38-50mm adjustment range.
| Power [ kW ] | 10 |
| Power [ kW ] | 25 |
| Power [ kW ] | 14 |
| Power [ kW ] | 20 |
| Weight [ kg ] | 467 |
| Weight [ kg ] | 372 |
| Weight [ kg ] | 340 |
| Weight [ kg ] | 350 |
| Height [ mm ] | 1,496 |
| Height [ mm ] | 1,446 |
| Height [ mm ] | 1,396 |
| Height [ mm ] | 1,396 |
| Width [ mm ] | 1,151 |
| Width [ mm ] | 1,201 |
| Width [ mm ] | 1,101 |
| Width [ mm ] | 1,201 |
| Depth [ mm ] | 815 |
| Depth [ mm ] | 835 |
| Depth [ mm ] | 960 |
| Depth [ mm ] | 835 |
| Exhaust gas pipe size [ mm ] | 159 |
| Exhaust gas pipe size [ mm ] | 159 |
| Exhaust gas pipe size [ mm ] | 159 |
| Exhaust gas pipe size [ mm ] | 159 |
| Combustion chamber capacity [ dm³ ] | 68 |
| Combustion chamber capacity [ dm³ ] | 112 |
| Combustion chamber capacity [ dm³ ] | 81 |
| Combustion chamber capacity [ dm³ ] | 68 |
| Feeder capacity [ dm³ ] | 141 |
| Feeder capacity [ dm³ ] | 199 |
| Feeder capacity [ dm³ ] | 152 |
| Feeder capacity [ dm³ ] | 141 |
| Water capacity [ L ] | 63 |
| Water capacity [ L ] | 71 |
| Water capacity [ L ] | 65 |
| Water capacity [ L ] | 103 |
| Min. Chimney height [ m ] | 7 |
| Min. Chimney height [ m ] | 7.5 |
| Min. Chimney height [ m ] | 6.5 |
| Min. Chimney height [ m ] | 6 |
| Min chimney draft [ Pa ] | 28 |
| Min chimney draft [ Pa ] | 26 |
| Min chimney draft [ Pa ] | 23 |
| Min chimney draft [ Pa ] | 20 |
| Min. chimney diameter [ mm ] | 170 |
| Min. chimney diameter [ mm ] | 160 |
| Min. chimney diameter [ mm ] | 160 |
| Min. chimney diameter [ mm ] | 160 |
| Efficiency [ % ] | 94.7 |
| EcoDesign | YES |
| Class | 5, A+ |
| Outlet and inlet supply size [ inch ] | 6⁄4'' |
| Installation | Floor |
| Max. operating pressure [ bar ] | 1.500 |
| Mains voltage [ V ] | 230 |
| Fuel | pellets |
| Warranty | 5 years for tightness of the heat exchanger |