The PROSAT DS BIO boiler is a new generation of manually fuel-loaded boilers with a modern design, designed for the combustion of solid fuels: hardwood logs. The boiler has a structure that includes two separate chambers. In one chamber, the fuel gasification process takes place, while in the other ceramic chamber, the gas combustion process occurs. It has a large loading chamber for suspended fuel, a metal-ceramic burner, and a vertical heat exchanger with flue gas channels equipped with flue gas baffles. It is also equipped with a draft switch to facilitate ignition (short flue gas circuit). Air with adjustable primary and secondary air supply is delivered to the combustion chamber and the ceramic nozzle. The burner contains a metal partition with secondary air supply, which provides oxygen for combustion in the ceramic swirl burner.

The boiler can be installed in both open and closed systems after installing the appropriate safety measures described in the manual.

Boiler construction:

PROSAT DS BIO Wood Gasifying Boiler
  1. Draft regulator sleeve
  2. Thermal insulation
  3. Supply inlet
  4. Flame sight glass
  5. Shortened flue gas valve lever
  6. Ashpan door
  7. Chimney cap
  8. Fill door
  9. Service door
  10. Ashpan door
  11. Bottom door damper
  12. Charging chamber
  13. Ceramic swirl burner
  14. Cast iron firebox grate
  15. Ashpan chamber
  16. Secondary air damper for the steel partition
  17. Secondary air damper for the ceramic burner
  18. Bottom cleanout
  19. Return inlet
  20. Air swirl device

The boiler body is made of 4 and 6 mm thick steel. It consists of the ashpan, firebox, and convection parts.

The ashpan is located at the bottom of the boiler (below the grate) and serves as a chamber for collecting ash. It is equipped with a drawer that facilitates ash removal through the ashpan doors. The doors are fitted with an air damper for regulating the supply of primary air to the combustion chamber.

The firebox is limited from below by a cast iron grate, where the fuel combustion (gasification) process takes place. In the rear part of the firebox (combustion chamber), there is a ceramic burner consisting of several ceramic elements. These elements may require periodic replacement due to high thermal loads. The firebox is closed with service doors (filling doors) through which manual fuel loading takes place. The filling doors have a flue draft control opening.

The convection part consists of a system of vertical water channels alternating with flue gas channels. In the last flue gas channel, there are baffles that cause swirling of the flue gas flow, slowing them down, and intensifying heat exchange. This channel is connected to the chimney connector, which links the boiler to the chimney installation. The upper part of the convection part contains cleaning doors for removing soot deposits.

The boiler has threaded connections for supply, return, and drain. The upper part of the boiler is equipped with connections for the water supply, while the lower part at the back or side of the boiler has connections for the water return and drain.

The thermal insulation is made of mineral wool placed in steel casings or double-coated with powder paint. The insulation prevents heat loss and ensures a safe external surface temperature. All doors are thermally insulated with ceramic plates, and the contact area between the doors and the body is sealed with a ceramic rope.

Technical Data

DataUnitDS BIO 9DS BIO 15DS BIO 20
Nominal heating power[kW]91520
Burning time[h]5
Boiler heating surface[m2]1.51.92.4
Boiler water capacity[L]637080
Approximate heated area[m2]120160220
Boiler class acc. to PN-EN 303-5:2012[-]ecodesign
Efficiency[%]89
Loading chamber capacity[kg]142025
Max. supply temperature[掳C]85
Min. supply temperature[掳C]55
Average flue gas temperature[掳C]145
Max. buffer tank water temperature[掳C]85
Max. allowable working pressure[MPa]0.2
Test pressure[MPa]0.35
Required chimney draft[mbar]0.20.25
Recommended buffer tank capacity[L]4507001000
Min. chimney cross-section[cm2]250400
Minimum chimney height[m]6
Flue outlet diameter[mm]160
Boiler weight[kg]270330370
Supply and return connection diameter[inch]11 1/2
Drain connection diameter[inch]3/4"
Noise emission[dB]<30
Loading opening dimensions[mm]300x220300x220360x220
Loading chamber dimensions[mm]600x300x220700x300x220700x300x300
Height[mm]9401050
Width[mm]480550
Depth[mm]800870