Wood gasifying boiler ATMOS Dokogen DC GD

Accessories

    Manufacturer: ATMOS
    ATMOS

    4 157,14 USD

    Payment and delivery

    Transport Costs: Individual calculation
    (After placing your order we will send you a non-binding offer containing delivery costs.)

    Payment methods for the goods:

    Bank transfereligible for a 2% discount for orders from Poland (others without discount)
    Cash on delivery – always without discount, available only in Poland and the Czech Republic (up to 8,000 PLN or 16,000 CZK, rest in bank trasfer)
    P24 – operator’s payment gateway, no discount for orders from Poland, others +2%

    Add to wishlist

    Total Rating Total Rating:

    5
    5,00/5 - 1 review

    View ratings
    0 1 2 3 41
    0 1 2 3 00
    0 1 2 0 10
    0 1 0 1 20
    0 0 1 2 30

     Add Review View Reviews View Reviews

    Accessories

     

    Dokogen DC GD boilers are wood gasifying boilers, it is the most efficient method, which consists in burning wood gas produced during thermal decomposition of wood with limited access to oxygen. Access to air and the combustion process are regulated by an exhaust fan. This makes it possible to start the boiler quickly and obtain a good quality of combustion from the moment it is started. The flame temperature is 1 000 - 1 250 °C.

    Dokogen boilers are characterised by a unique fireplace, lined with ceramic fittings. At the bottom, the furnace has holes for the supply of heated primary air, a gasifying nozzle with holes for the supply of secondary air and a lower chamber with a ceramic spherical space. The rear flue gas duct, on the other hand, has a tubular exchanger.

    Komora zasypowej

    View of the charging chamber

    Widok dolnej komory spalania

    View of the lower combustion chamber

    Wentylator wyciągowy i króciec dymowy

    Exhaust fan and smoke autlet

    Wymiennik rurowy

    Pipe heat exchanger

    Advantages of ATMOS wood gasifying boiler

    • ability to burn large pieces of wood;
    • large fuel tank (long combustion time);
    • tubular heat exchanger;
    • Sprawność wynosi powyżej 90%;
    • Ecological combustion (5th class according to ČSN EN 303-5, ECODESIGN 2015/1189);
    • Exhaust fan (ash removal without dust);
    • Cooling coil (protection against overheating of the boiler);
    • Automatic shutdown of the fan after fuel burnout;
    • Large ash collector (when burning wood, cleaning once a week);
    • Small and lightweight;
    • High quality
    Boilers meet the limits for Ecological Products. According to ČSN EN 303-5, the boilers meet the requirements of the 5th class. They meet the strict requirements of EU - EKODESIGN 2015/1189.

    ATMOS boilers must be connected via LADDOMAT or thermoregulation valve (can be purchased from us in the shop) in order to reach the minimum return water temperature of 65°C. Outgoing water from the boiler must be kept at 80 - 90°C.

    Boiler control

    Boiler regulation is electromechanical, it is provided by the air control valve controlled by the draught regulator type FR 124, which according to the set output water temperature (80 - 90 °C) automatically opens or closes the air valve. A lot of attention must be paid to the setting of the output regulator, as it protects the boiler against overheating. The boiler is equipped with a control thermostat located on the boiler panel, which controls the exhaust fan according to the set output temperature (80 - 85 °C). The temperature on the control thermostat should be set 5 °C lower than the temperature on the draught regulator type FR 124. Boilers are additionally equipped with a flue gas thermostat, which is used to switch off the exhaust fan after burning fuel.

    Klapka regulacji powietrza

    Air adjustment flap

    Regulator ciągu

    Thrust regulator type FR 124

    Basic components of the boiler Atmos Dokogen DC

    Atmos Dokogen DC
      1. Boiler body;
      2. Loading door (top);
      3. Ashtray door - combustion chamber (lower);
      4. Exhaust fan (S);
      5. Heat-resistant moulded part - nozzle;
      6. Control panel;
      7. Safety thermostat;
      8. Control valve;
      9. Heat-resistant moulded part, rtpe GD, side of the hearth;
      10. Heat-resistant shape - type GD - in spherical space;
      11. Sealer - nozzles - 12x12 (14x14);
      12. Heat-resistamt shape - crescent;
      13. Lightning valve;
      14. Heat-resistamt shape - type GD - rear face of spherical space;
      15. Cleaning cover;
      16. Frame cover;
      17. Heating valve pull;
      18. Thermometer;
      19. Supply air duct;
      20. On/Off switch with indicator;
      21. ----
      22. Thrust regulator - Honeywell FR 124;
      23. Cooling loop against overheating;
      24. Control fan thermostat (boiler);
      25. Door filling - Sibral;
      26. Door sealant - rope 18x18;
      27. Flue gas thermostat;
      28. ----
      29. ----
      30. Fan capacitor - 1μF;
      31. ----
      32. ----
      33. Pipe heat exchanger.

    K - Conduit connection

    L - Boiler water outlet

    M - Boiler Water intel

    N - Base of the filling tap

    P - Connection for valve sensor to control the cooling spiral

    Boiler dimensions Atmos Dokogen DC

    Boiler Type
    DC18GDDC25GDDC30GDDC40GDDC50GD
    A12811281128114351435
    B8201020102011201120
    C680680680680680
    D94594594510951095
    E150/152150/152150/152150/152150/152
    F8787878278
    G185185185185185
    H10081008100811521152
    CH256256256256256
    I256256256256256
    J6/4"6/4"6/4"2"2"

    Technical data

    Boiler Type
    DC18GDDC25GDDC30GDDC40GDDC50GD
    Boiler power
    kW192529,54049
    Recomended chimney draught
    Pa1618202224
    Max pressure working water
    kPa250250250250250
    Boiler weight
    kg376469466548565
    Water volume in the boilerl73105105112128
    Fuel well capacity
    dm385125125170170
    Max length of wood
    mm330530530530530
    Diameter of the exhaust pipe
    mm150/152150/152150/152150/152150/152
    Effciency%90,390,590,890,592
    Exhaust gas temperature at rated power
    °C145132155175183
    Required fuel (recomended)
    Dry wood with a calorfic value of 15 - 18 MJ/kg, diameter 80 - 150 mm and humidity 12 - 20%
    Minimum return flow temperature
    °C65
    Boiler class
    5
    Energy effciency class
    A+
    EKODESIGNYES

    Data sheet

    EcoDesignYES, wood
    Class5
    Width [ mm ]680
    Max. operating pressure [ bar ]2,5

    ℹ️ Viewed reviews are moderated. We do not verify that they come from customers who have purchased the product.

     Reviews about Wood gasifying boiler ATMOS Dokogen DC GD (1)

    2021-01-20
    Andrzej
     Report abuse

    Najsprawniejszy w swojej klasie

    Polecam ten kocioł każdemu kto ma minimalne checi do rozpalenia i dostęp do drewna wtedy to najtańsze palenie (po zrębkach) w ostre zimy również od pompy ciepła ok 4-7gr/ kWh zależnie od rodzaju, ceny i wilg drewna
    Szczapy 55cm i 160l komory + bufor pozwala na wygenerowanie dużej ilości ciepła

    Cena:
    Funkcjonalność:
    Jakość:
    Page: 1

    6 other products in the same category:

    Product related articles on blog

    No related articles on blog

    6 other products in the same category:

    Download