DRACO BIO D is the leading model of the BIO series boiler, featuring a highly efficient single-furnace heat exchanger with an enlarged heat reception surface. The boiler is equipped with a self-cleaning pellet burner made of heat-resistant steel, installed in the front door of the unit (in the 50 model, the burner is installed on the side of the exchanger). The burner grate contains openings that provide air for combustion, supplied by a fan directly mounted on the air mixer. The boiler’s heat exchanger is made of high-quality certified steel with a thickness of 8 mm. The operation of the boiler is controlled by a modern electronic regulator with a colorful touchscreen LCD display.
| TECHNICAL PARAMETERS | Unit | DRACO D BIO 15 | DRACO D BIO 22 | DRACO D BIO 30 | DRACO D BIO 40 | DRACO D BIO 50 | |
| Nominal power | kW | 15 | 22 | 30 | 40 | 49 | |
| Efficiency | Nominal power | % | 92 | ||||
| Minimal power | 93 | 92 | 93 | ||||
| Seasonal efficiency | % | 81 | 82 | ||||
| Seasonal emissions | PM | mg/m3 | 17 | 16 | 18 | 17 | |
| OGC | 16 | 14 | 13 | 9 | 11 | ||
| CO | 169 | 273 | 250 | 261 | 258 | ||
| NOx | 120 | 147 | 125 | 145 | 111 | ||
| Power adjustment range | kW | 4.5 ÷ 15 | 6.6 ÷ 22 | 9 ÷ 30 | 12 ÷ 40 | 14.7 ÷ 49 | |
| Fuel type | - | Pellet | |||||
| Fuel class | - | C1 | |||||
| Fuel consumption | Nominal power | kg/h | 3.5 | 5 | 7 | 8.8 | 11.3 |
| Minimal power | 1 | 1.3 | 1.9 | 2.6 | 3.2 | ||
| Burn time (nominal power) | h | 45.7 | 32 | 22.8 | 25 | 19.5 | |
| Flue gas temperature | Nominal power | °C | 109 | 107 | 118 | 119 | 128 |
| Minimal power | 77 | 81 | 75 | 74 | 76 | ||
| Boiler class | - | 5 | |||||
| Energy efficiency class | - | A+ | |||||
| EEI factor | - | 119 | 120 | 121 | |||
| Weight (boiler/storage) | kg | 355 / 34 | 444 / 34 | 511 / 34 | 588 / 41 | 715 / 41 | |
| Boiler heating surface | m2 | 2.5 | 3.3 | 4.3 | 4.2 | 6.1 | |
| Water volume | dm3 | 75 | 125 | 150 | 130 | 224 | |
| Required chimney draft (min ÷ max power) | Pa | 10 ÷ 20 | 20 ÷ 30 | ||||
| Boiler dimensions with storage | Width | mm | 1200 | 1230 | 1280 | ||
| Depth | 1170 | 1230 | 1350 | 995 | 1145 | ||
| Height | 1500 | 1545 | 1645 | 1650 | |||
| Flue gas outlet diameter | mm | 160 | |||||
| Fuel storage volume | l | 240 | 340 | ||||
| Fuel storage capacity | kg | ~160 | ~220 | ||||
| Storage loading opening dimensions | mm | 600x600 | 670x670 | ||||
| Max working water pressure | bar | 1.5 | |||||
| Fluid group | - | 2 - water | |||||
| Recommended working water temperature | °C | 65 ÷ 80 | |||||
| Max working water temperature | °C | 90 | |||||
| Min return water temperature | °C | 55 | |||||
| Max allowable heating medium level | m | 15 | |||||
| Safety valve | bar | 1.5 | |||||
| Heating and return water connections | Js | G 1½" | G 2" | ||||
| Flue gas mass flow | Nominal power | g/s | 9.5 | 13.7 | 17.8 | 26 | 29.3 |
| Minimal power | 4.5 | 5.2 | 8.4 | 12 | 13.9 | ||
| Connection voltage | - | 1 PEN~50 Hz | |||||
| Power consumption | Nominal power | W | 53 | 70 | 81 | 162 | 173 |
| Minimal power | 35 | 41 | 51 | 43 | 53 | ||
| Standby | 4.1 | 4 | |||||
| Electric Power Consumption (Gearbox/Blower/Igniter) | W | 50/45/300 | 50/85/300 | ||||
| Electrical Insulation | - | IP 40 | |||||



| Dimensions | Unit | DRACO D BIO 15 | DRACO D BIO 22 | DRACO D BIO 30 | DRACO D BIO 40 | DRACO D BIO 50 |
| A | mm | 1200 | 1230 | 1230 | 1880 | 1880 |
| A1 | mm | 470 | 530 | 530 | 660 | 660 |
| A2 | mm | 610 | 680 | |||
| A3 | mm | 75 | 85 | 90 | ||
| A4 | mm | 235 | 265 | 330 | ||
| A5 | mm | 75 | 85 | 90 | ||
| A6 | mm | - | 1180 | 1150 | ||
| B | mm | 1170 | 1230 | 1350 | 995 | 1145 |
| B1 | mm | 620 | 655 | 775 | 675 | 860 |
| B2 | mm | 190 | 195 | 190 | ||
| B3 | mm | 610 | 680 | |||
| B4 | mm | 360 | - | |||
| C | mm | 1440 | 1545 | 1645 | 1650 | |
| C1 | mm | 1180 | 1290 | 1380 | ||
| C2 | mm | 1500 | ||||
| C3 | mm | 75 | ||||
| C4 | mm | 60 | ||||
| C5 | mm | 180 | 190 | |||
| C6 | mm | 1340 | 1400 | |||
| Mains voltage [ V ] | 230 |
| Fuel | pellets |
| Warranty | 5 years for tightness of the heat exchanger |
ℹ️ Viewed reviews are moderated. We do not verify that they come from customers who have purchased the product.